Rev: 3 • Jun 12, 2017, 12:00 PMET EXPLOIT Win32/Industroyer DDOS Siemens SIPROTEC (CVE-2015-5374)
alert udp any any -> $HOME_NET 50000 (msg:"ET EXPLOIT Win32/Industroyer DDOS Siemens SIPROTEC (CVE-2015-5374)"; dsize:18; content:"|11 49 00 00 00 00 00 00 00 00 00 00 00 00 00 00 28 9E|"; fast_pattern; reference:url,www.welivesecurity.com/wp-content/uploads/2017/06/Win32_Industroyer.pdf; classtype:attempted-dos; sid:2024376; rev:3; metadata:attack_target Client_and_Server, created_at 2017_06_12, cve CVE_2015_5374, deployment Perimeter, deployment Internal, performance_impact Low, confidence High, signature_severity Major, updated_at 2020_08_19;)
Jun 12, 2017, 12:00 PM
Aug 19, 2020, 12:00 PM
Sep 21, 2024, 3:00 AM
May 30, 2025, 12:04 AM
rules/emerging-exploit.rules