ET WEB_SPECIFIC_APPS Rockwell Powermonitor 1000 firstrun Authentication Bypass Attempt

SID: 2062617Rev: 134 views
Sourceet/open
CreatedMay 28, 2025
UpdatedMay 28, 2025
Classificationattempted-admin
alert http any any -> $HOME_NET any (msg:"ET WEB_SPECIFIC_APPS Rockwell Powermonitor 1000 firstrun Authentication Bypass Attempt"; flow:established,to_server; http.uri; content:"/firstrun/cgi-bin/security"; fast_pattern; reference:url,claroty.com/team82/research/attention-high-voltage-exploring-the-attack-surface-of-the-rockwell-automation-powermonitor-1000; classtype:attempted-admin; sid:2062617; rev:1; metadata:affected_product Allen_Bradley_Rockwell_Automation_Series, attack_target ICS, tls_state plaintext, created_at 2025_05_28, deployment Perimeter, deployment Internal, performance_impact Low, confidence High, signature_severity Major, tag Exploit, updated_at 2025_05_28, mitre_tactic_id TA0001, mitre_tactic_name Initial_Access, mitre_technique_id T1190, mitre_technique_name Exploit_Public_Facing_Application; target:dest_ip;)

Metadata

affected productAllen_Bradley_Rockwell_Automation_Series
attack targetICS
tls stateplaintext
created at2025_05_28
deploymentInternal
performance impactLow
confidenceHigh
signature severityMajor
tagExploit
updated at2025_05_28
mitre tactic idTA0001
mitre tactic nameInitial_Access
mitre technique idT1190
mitre technique nameExploit_Public_Facing_Application